CERRO TOLOLO INTER-AMERICAN OBSERVATORY INSTRUMENT SECTION FILTER TRANSMISSION SCANNER FILTER IDENTIFICATION 5755/20 DATE OF MEASUREMENT FILTER SIZE 2 X 2 X .238 INCH FOCAL RATIO 13.5 TEMPERATURE [C] 22 PEAK WAVELENGTH [A] 5753 PEAK TRANSMISSION [%] 60.5 CENTER WAVELENGTH [A] 5754.5 BANDWIDTH [A] 21 COMMENTS: 5755/20-SFI WAVELENGTH TRANSMISSION 5700 .318725 5702 .372539 5704 .536193 5706 .564668 5708 .700054 5710 .434428 5712 .545852 5714 .601751 5716 .769442 5718 .799118 5720 1.05118 5722 1.05761 5724 1.67504 5726 1.854 5728 2.31281 5730 2.79639 5732 3.70695 5734 5.09666 5736 7.14916 5738 10.1885 5740 15.1632 5742 22.1299 5744 31.0458 5746 41.1114 5748 50.6344 5750 56.8134 5752 60.1705 5754 60.8908 5756 59.7613 5758 57.9142 5760 53.492 5762 45.114 5764 36.6355 5766 27.543 5768 20.2524 5770 14.4928 5772 10.2507 5774 7.38853 5776 5.58036 5778 4.23213 5780 3.33226 5782 2.52101 5784 2.27125 5786 1.66178 5788 1.50622 5790 1.31234 5792 1.15359 5794 .925008 5796 .798403 5798 .734803 5800 .672947 5802 .878082 5804 .775978 5806 .443989 5808 .375811 5810 .411523 5812 .379834 5814 .451703 5816 .764951 5818 .699056 5820 .769769