CTIO FILTERS

Recent measurements

Transmission measurements made in January 2001 with our fiber optics spectrometer facility (description here).

 
Filter Old Plot Data Size Thick Cent Fwhm Trans F# Selec FiltSet Comments/cosmetics
/width meas     (") (mm) (Å) (Å) (%)   Filt    
                         
4861/44 old plot  data  2x2 6.1 4864 40 77.0 0 1 H beta set one face coated
5007/44 old plot  data  2x2 6.2 5007 38 74.5 0 1 H beta set one face coated
6563/78 old plot  data  2x2 6.1 6568 68 80.4 0 2 H alpha set  
6575/14 old plot  data  2x2 12.3 6571 18 64.7 0 2 Old Fabry Perot LMC Redshift  
                         
3700/415 old plot  data  3x3   3700 415 65.9 0 3 U Landolt liquid CuSO4 (Tek set #3 ??)  
4203/1050 old plot  data  3x3 5.3 4225 996 63.8 0 3 B Tek set#3  
5588/1127   plot  data  3x3 5.1 5605 1152 79.5 0 3 V Tek set#3  
6410/1470 old plot  data  3x3 5.2 6414 1474 78.9 0 1,2 R Tek set#3  
8067/1485 old plot  data  3x3 6.1 8056 1434 90.0 0 1,2 I kc Tek set#3  
                         
3666/333   plot  data  4x4 5.1 3666 333 60.0 0 3 SDSS u  
4680/1530   plot  data  4x4 5.2 4680 1530 88.3 0 1 SDSS g  
6350/1347   plot  data  4x4 5.0 6350 1347 97.0 0 1,2 SDSS r  
7736/1516   plot  data  4x4 5.2 7736 1516 93.0 0 2 SDSS i  
9926/3198   plot  data  4x4 4.8 9926 3198 99.0 0 2 SDSS z  
                         
3727/50   plot  data  5.75 5.3 3727 49 43.5 0 1 [OII] 5mm chip in corner, median of 32 points




SCANS: 20x20mm grid of points starting 10mm from the edges. Shows spatial uniformity of coating.

Filter Old Plot Data Size Thick Cent Fwhm Trans F# Selec FiltSet Comments/cosmetics
/width meas     (") (mm) (A) (A) (%)   Filt    
                         
3727/50   plot    5.75 5.3 3727 49 43.5 0 1 [OII] standard deviation of transmission vs. wavelength


Written by Constanza Araujo, 1 February 2001

Send comments to Maxime Boccas